Vasily Grachev
Radiologist with 20+ Years of Experience
  • Founder of independent radiodiagnostic networks 3DLab (Russia) and KolibriX (Kazakhstan).
  • Expert with Diagnocat AI, Planmeca KOL,
  • instructor and consultant on integrating CBCT into clinical workflows.

Focus — clinical value of CBCT, not just pretty images.

Why CBCT Quality Matters

CBCT is the foundation of all digital and clinical decisions. Any error during image acquisition automatically affects the entire treatment workflow.


1. Typical Errors

  • incorrect exposure parameters (kV/mA/time),
  • wrong field of view (FOV),
  • patient movement,
  • geometric distortion,
  • lack of calibration.

2. What This Leads To

  • implant planning errors,
  • incorrect surgical guides,
  • distortion when matching optical scans,
  • problems in orthodontic planning,
  • faulty data for dental labs,
  • missed pathologies (by clinicians and AI),
  • no objective follow-up.
Summary
Not just one defect — a cascade of systemic errors leading to clinical instability and loss of patient trust.
[ services ]

I. Expert CBCT Quality Audit & Systemic Error Elimination

  • Problem
    Clinicians are unhappy with scans → they call an engineer → “calibration” → issue persists → time and money wasted.
  • CAUSES
    Most errors are not technical but human: exposure settings, FOV, positioning, motion. Engineers don’t assess clinical quality.
How I Solve It
  1. image analysis to identify the real cause
  2. on-site QA phantom check or remote diagnostics
  3. evaluation of equipment, protocols, and staff performance
  4. a detailed action plan: what to fix, reconfigure, or train
  5. if needed — bring a vetted engineer under my supervision
DURATION
  • 1.5–2.5 hours

PRICE:
  • Moscow: from 15,000 ₽
  • Moscow region: from 20,000 ₽
  • Online audit: from 10,000 ₽

OUTCOME:
Stable scan quality and elimination of systemic errors

II. Staff Training

  • PROBLEM
    The CBCT scanner sits idle or is underused because the assistant changed or staff lacks confidence.
How I Solve It
  1. hands-on training on your equipment
  2. FOV, positioning, exposure tailored to clinical needs
  3. practice on real cases
  4. evaluation exam
  5. quality self-control training
  6. month of free follow-up support
DURETION:
  • 4–6 hours

PRICE:
  • On-site training: from 30,000 ₽
  • Online (Planmeca): from 15,000 ₽

OUTCOME:
Confident staff delivering clinically accurate images

III. CBCT Clinical Standards Implementation

  • PROBLEM
    Clinic has a CBCT scanner but doctors don’t prescribe scans → equipment doesn’t generate revenue.
  • CAUSES
    • no clinical understanding
    • no diagnostic standard
    • no patient communication strategy
    • relying on old/poor quality scans
How I Solve It
  1. lecture + practical case workshop
  2. software training (including Diagnocat)
  3. legal aspects of documentation
  4. CBCT standard for initial consultation
  5. interdisciplinary protocols
DURATION:
  • 1–2 days

PRICE:
  • 1 day: 100,000 ₽
  • 2 days: 150,000 ₽
  • Russia (travel included): from 150,000 ₽

OUTCOME:
Confident clinicians applying consistent standards

IV. CBCT Equipment Selection & Integration

  • PROBLEM
    Clinic chooses equipment based on price or dealer advice → wrong model → no replacement → mismatch with clinical tasks.
How I Solve It
  1. interview with owners and doctors
  2. task analysis
  3. model selection + real image examples
  4. used equipment inspection with engineers
  5. support with room layout, radiation shielding, IT
  6. post-installation training
  7. standards implementation
PRICE:
  • Online consulting: from 10,000 ₽
  • Full support: 150,000–200,000 ₽

V. Expert CBCT Reporting for Clinics

  • PROBLEM
    Complex cases, ambiguous findings, medicolegal questions, no in-house radiologist.
How I Solve It
  1. standardized reporting system
  2. contractual cooperation
  3. expert reports with video breakdown
  4. AI report verification
  5. customizable clinic templates
PRICE:
  • Implementation: on request
  • Monthly plans by volume
  • Per expert report from 5,000 ₽

VI. Independent CBCT Second Opinion for Patients

  • PROBLEM
    Patient doesn’t understand diagnosis, has doubts, seeks an independent evaluation.
КАК РЕШАЮ Я:
  1. expert report
  2. video explanation
  3. clear language
  4. medicolegally compliant documentation
PRICE:
  • from 5,000 ₽

Testimonials & Gallery

Vasily Grachev
Founder of independent radiodiagnostic networks
3DLab (Russia) and KolibriX (Kazakhstan).
📍 Moscow / Online — serving Russia & CIS
📩 vg@cbctpro.ru
🌐 cbctpro.ru